Ultrasonic Time of Flight Flow Meters

Model FS-555 Ultrasonic Flowmeter
Model FS-595 Ultrasonic Flowmeter Kit

 

Sparling Model FS-555

The Sparling Series 555 is a self-diagnosing third generation ultrasonic flow meter. Built-in diagnostics detect application problems, transducer and cable malfunctions and most circuit failures. Continued signal loss initiates a pre-selected output of either 0 or 100% of span.

Automatic zero options are unnecessary. If the pipe is empty, the S-555 will automatically indicate the preselected fail safe output. A built-in low flow cutoff inhibits output when the flow rate drops below 2% of full scale.

Field calibration is simple and straightforward. A 3-position switch is used to set the variables of meter zero, current output zero and span. Built-in LED's indicate proper meter zero. Current output zero (0 or 4 ma) and span are set using an external milliammeter or the optional built-in LCD rate indicator.

All transmitters are interchangeable. The S-555 has no VCO's to require selection to the pipe diameter. Spare parts stocking is simplified.

Obstructionless flow
Pressure drop equal to an equivalent length of straight pipe
Unaffected by changes in temperature, density or viscosity.
Standard bi-directional flow capability
Standard low flow cutoff
Standard 4-20 mA output with optional scaled pulse output
Standard corrosion-resistant self-diagnosing transmitter.
Optional transmitter-mounted LCD indicator and totalizer.
Accuracy 1% of rate
Low power consumption - four watts for all sizes

For more information request PDS-555.

 

Sparling Model FS-595 Sensor Kit

The FS-595 kit contains all parts - transducers, mounting bosses, hardware, installation template and instructions - needed to install a Sparling transmissive ultrasonic liquid flowmeter sensor in an existing or under-construction pipeline.

A template quickly and accurately locates and centers transducer mounting holes while automatically compensating for deviation from nominal pipe diameter. Holes for transducers are round and straight, no difficult angles, drilled perpendicular to the tube. All critical angles and dimensions of the transducer mounts are precisely machined at the factory. Final alignment is performed with a 1/2" or 3/4" straight pipe (not included) slipped through the two transducer housings before welding.


Obstructionless flow
Pressure drop equal to an equivalent length of straight pipe
Unaffected by changes in temperature, density or viscosity.
Standard bi-directional flow capability
Standard low flow cutoff
Standard 4-20 mA output with optional scaled pulse output
Standard corrosion-resistant self-diagnosing transmitter.
Optional transmitter-mounted LCD indicator and totalizer.
Accuracy 1% to 2% of rate depending on precision of installation

Limitations
The flowmeters operating principle requires that high frequency sound be reliably transmitted across the pipe. Liquid slurries with excess solids or with entrained gases may block the ultrasonic pulses. Ultrasonic flowmeters are not recommended for the following liquids: primary sludge, mixed liquor, aerobically digested sludge, dissolved air flotation thickened sludge and its liquid phase, septic sludge, activated carbon sludge. Liquids with entrained gases cannot be measured reliably.


For more detailed information, request literature or contact your local Sparling Representative.